NOT ALL RJ-45S ARE CREATED EQUAL
FEATURING SENTINEL CONNECTOR SYSTEMS - WHEN SIGNAL INTEGRITY MATTERS
          Shipping Over 100,000,000 RJ45 Plugs a Year - MADE in USA

Cage Code 71SB6   DUNS 191497254    P:630-659-6337    dave@rj45s.com
Category 6 28 AWG Reduced Diameter

Patch Cords


100% Tested and Certified to ANSI/TIA 568-C.2 using Fluke Networks DSX CableAnalyzer™ Series or Softing WireXpert 4500 Cable Certifier
Test Reports included with each shipment



ALL PATCH CORDS  ARE NOT  CREATED EQUAL
           


85% Of Imported Category 6 Patch Cords Fail Electrical Testing

78% fail by more than 3db.....45% Fail by more than 6db

These failure rates can have a dramatic effect on your networks performance.


Nowhere in the industry is there a bigger problem than with the selection of Category 6 and 6A Patch Cords that meet BOTH Electrical Performance Testing AND Mechanical/Material Specifications. For example, FLUKE NETWORKS Application Note entitled “The Weakest Link in High-Performance Cabling Systemspoints out that the Patch Cord incorporating a modular RJ45 plug is the weakest link in the Signal Transmission Channel. They have found that 83% OF ALL PATCH CORDS FAIL TO MEET THE PRESCRIBED ELECTRICAL STANDARDS OF THE TIA. The impact of these cables that affect ALIEN CROSSTALK, RETURN LOSS, LATENCY and DELAY SKEW will adversely affect network performance and speeds.


Similarly, the Communications Cable and Connectivity Association (CCCA) has concluded a research study that indicated an 85% Failure Rate in Category 6 patch cords produced offshore by companies who are largely unknown in North America. What is more disturbing is that 78% of the failing samples failed by a margin of 3dB or more and 45% of the failing samples failed by margin of 6dB or more.  Because noise is measured on a logarithmic scale, a 3dB failure indicates a noise level that is twice as high as the allowable standards and failures of this magnitude contribute to significant network problem.


Regarding Mechanical/Material Specifications, Sentinel Connector Systems has made a presentation to the FCC on problems associated with RJ45s with reference to the ANSI/TIA 1096-A Standard (formerly FCC Part 68). Quality Issues include Gold Plating, Material Selection, Contact Lift-Off and a host of other problems. ACTA Virtual Public Meeting – ANSI/TIA 1096-A Non-Compliance Issues (Focus on RJ45). What is even more disturbing is that they also found a 94.4% Failure To Meet Minimum ANSI/TIA 1096-A Specification Rate among Modular Connector supplies.



THE SOLUTION
HOW WE DO THINGS

100% PERFORMANCE TESTED and CERTIFIED - All cables are 100% PERFORMANCE TESTED and CERTIFIED using Fluke Networks DSX CableAnalyzer™ Series or Softing WireXpert 4500 test Equipment to current TIA and ISO Standards. A copy of the test report is included with each shipment and the TEST RESULTS are stored on a SECURE SERVER for seven (7) years. Customers can Log-In to their password protected data at any time.

TRAINING
-
Each assembly line operator goes through an extensive 8 week training program before they actually see the production line. This intense training insures operator to operator consistency, guarantees high yields with few rejects and provides the Workmanship that has allowed us to receive the HIGHEST VENDOR RATINGS from our Customers.

COMPONENT SELECTION
- We only use the BEST MADE IN AMERICA Sentinel Connector PATENTED RJ45 Plugs and Sentinel Approved bulk patch cable suppliers.

TEST and TERMINATION EQUIPMENT - CALIBRATION - FIXTURES - MAINTENANCE
We use Industry Standard Analyzers to test each patch cable and have an array of Test Equipment and Fixtures to support and insure that TEST EQUIPMENT is calibrated and the TEST REPORTS are accurate. A regularly scheduled maintenance program insures that all tooling is calibrated, in good working condition and in compliance with ANSI/TIA 1096-A (formerly FCC Part 68.5) dimensional specifications.....as well as exceeding specifications set forth by the IEEE, IEC and ISO Standards bodies. All tooling is CALIBRATED DAILY before production begins to insure that the proper blade depth of .237” +/- .005” is maintained. Tooling is checked periodically for wear and a defined maintenance procedure is in place.
  
        

                                        
                                                  CATEGORY 6 28 AWG

PATCH CORD PRODUCT MATRIX

 Description HOT
PRODUCT


Cat 6
U/UTP 
28 AWG

(.150" OD)


NEW USA  
HOT 
PRODUCT

Cat 6
U/UTP 
28 AWG

(.145" OD)



 
 

Country
of
Origin



Plugs & Boots
USA


Cable

USA
Plugs & Boots
USA


Cable

TAA


 Black



6UA28BLK



6UA28BLKS

with
SERIAL NUMBER


6U28BLK


6U28BLKS
with
SERIAL NUMBER


 Blue



6UA28BLU


6UA28BLUS
with
SERIAL NUMBER


6U28BLU


6U28BLUS
with
SERIAL NUMBER 

 Green


6UA28GRN


6UA28GRNS
with
SERIAL NUMBER



6U28GRN


6U28GRNS
with
SERIAL NUMBER



 Grey



6UA28GRY


6UA28GRYS
with
SERIAL NUMBER

 
6U28GRY


6U28GRYS
with
SERIAL NUMBER
 

 Orange



6UA28ORN


6UA28ORNS
with
SERIAL NUMBER

 
6U28ORN

6U28ORNS
with
SERIAL NUMBER
 

 Purple



6UA28PUR


6UA28PURS
with
SERIAL NUMBER


 6U28PU


6U28PURS
with
SERIAL NUMBER


 Red



6UA28RED


6UA28REDS
with
SERIAL NUMBER

 
 6U28RED


6U28REDS
with
SERIAL NUMBER


 White



6UA28WHT


6UA28WHTS
with
SERIAL NUMBER

 
6U28WHT

6U28WHTS
with
SERIAL NUMBER
 
 
Yellow



6UA28YEL


6UA28YELS
with
SERIAL NUMBER

 
6U28YEL


6U28YELS
with
SERIAL NUMBER
 




  

                                                                                                  
                           

For more information, contact
dave@rj45s.com
RJ45s.com
2400 East Main Street
St Charles, IL  60174
phone: 630-659-6337

Website Builder