CAVEAT EMPTOR.....Let The Buyer Beware
SUB-STANDARD, NON-COMPLIANT and COUNTERFEIT RJ45's coming in from the Far East
KNOW THE STANDARDS - KNOW THE SPECS - INSIST ON COMPLIANCE - KNOW YOUR SUPPLIERS
ALL PRODUCTS MEET/EXCEED THE FOLLOWING STANDARDS
ANSI/TIA-568.2-D - ANSI/TIA 1096-B (Formerly FCC Part 68)
CENELEC EN 50173 - IEC 60603 - ISO-8877 - ISO/IEC 11801 - UL 1863 (1000v)
Part Number Click on Blue Link for Detailed Specs |
Category |
Contact Design |
Insulated Conductor OD |
Jacket OD |
Picture |
106S08080058C34 Cage Code 71SB6 NSN 5935-01-528-2544 5935-01-576-2614 5935-01-560-2961 |
Category 5e |
4 over 4 |
Up to .048" |
Up to .265" |
![]() |
106S080800D6H34 For use with STRANDED CONDUCTORS ONLY |
Category 6 |
4 over 4 |
.054" - .058" |
Up to .310" |
![]() |
110S080820-24 |
Category 3 |
8 Across |
Up to .040" |
.240"- .260" |
![]() |
110S080820C24 |
Category 3 |
8 Across |
Up to .040" |
.240"- .260" |
![]() |
111S08080016-34 |
Category 5e |
4 over 4 | .037"- .042" |
.240"- .260" |
![]() |
111S08080028C34 |
Category 5e |
4 over 4 |
.037"- .042" |
Up to .265" |
![]() |
111S08080028L34 |
Category 5e |
4 over 4 |
.037"- .042" |
.240"- .260" |
![]() |
111S08080054C34 |
Category 6 |
4 over 4 |
.037"- .042" |
Up to .265" |
![]() |
111S08080054H34 |
Category 6 |
4 over 4 |
.037"- .042" |
Up to .310" |
![]() |
111S08080054L34 |
Category 6 |
4 over 4 |
.037"- .042" |
.240"- .260" |
![]() |
111S08080056-34 |
Category 5e |
4 over 4 |
.039"- .043" |
.240"- .260" |
![]() |
111S08080056C34 Cage Code 71SB6 NSN 5935-01-591-2843 |
Category 5e |
4 over 4 |
.039"- .043" |
Up to .265" |
![]() |
111S08080062L34 AND 111S08080063L34 |
Category 6 |
2 over 6 AND 6 over 2 |
.037"- .042" |
.240"- .260" |
![]() |
111S08080090C34 |
Category 6 |
4 over 4 | .044"- .048" |
Up to .265" |
![]() |
111S08080090H34 |
Category 6 and 6A |
4 over 4 |
.044"- .048" |
Up to 310" |
![]() |
111S08080090L34 |
Category 6 |
4 over 4 | .044"- .048" |
.240"- .260" |
![]() |
111S08080091C34 |
Category 6 |
4 over 4 |
.048"- .052" |
Up to .265" |
![]() |
111S08080091H34 |
Category 6 and 6A |
4 over 4 |
.048"- .052" |
Up to 310" |
![]() |
111S08080091L34 |
Category 6 |
4 over 4 |
.048"- .052" |
.240"- .260" |
![]() |
111S08080095HA4 |
Category 6 |
8 Across |
.037"- .042" |
Up to .310" |
![]() |
111S08080095LA4 |
Category 6/6a |
8 Across |
.037"- .042" |
.240"- .260" |
![]() |
111S080800C7LA4 For Use With STRANDED CONDUCTORS ONLY |
Category 6/6a |
8 Across |
.037"- .040" |
.194" Max |
![]() |
111S080800D4LA4 For Use With STRANDED CONDUCTORS ONLY |
Category 6/6a |
8 Across | .030" - .035" |
.194" Max |
![]() |
111S080800F3LA4 For Use With STRANDED CONDUCTORS ONLY |
Category 6/6a |
8 Across |
.031" - .033" |
.186" Max |
![]() |
114S040800C34 |
N/A |
1, 2, 3 and 6 |
.055"- .060" |
Up to .265" |
![]() |
Part Number |
Category | Contact Design |
Insulated Conductor OD |
Jacket OD |
Picture |